Futrex Scale -5000/XL Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Drucken & Scannen Futrex Scale -5000/XL herunter. Futrex Scale -5000/XL User's Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 35
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
USER'S MANUAL
FUTREX
7
77
7
-5000/XL
BODY FAT AND FITNESS COMPUTER
FUTREX INC.
130 Western Maryland Pkwy
Hagerstown, MD 21740
Version 8.4
Seitenansicht 0
1 2 3 4 5 6 ... 34 35

Inhaltsverzeichnis

Seite 1 - BODY FAT AND FITNESS COMPUTER

USER'S MANUAL FUTREX7777-5000/XL BODY FAT AND FITNESS COMPUTER FUTREX INC. 130 Western Maryland Pkwy Hagerstown, MD 21740

Seite 2

9 10) Enter Height in inches or cm (whole numbers only: e.g. 68 in. is acceptable). Refer to page 23 to switch between English and Metric units.

Seite 3 - 1.Main Body

10 2 Moderate aerobic activity (e.g. recreational volleyball, moderate speed walking). 1 Light aerobic activity (e.g. normal walking, golfing). 1

Seite 4

11 13) Press ENTER. The display will flash a decimal point following the number "1". Then the number "2" will be displayed.

Seite 5

12 Off Message An Off Message will appear and the FUTREX-5000/XL Automatic Power Down feature will turn the unit off if the user has not pressed a

Seite 6

13 2) Using a 12" ruler or the scale provided on the Arm Band, measure the length between the armpit and the inside of the elbow. 3) To

Seite 7

14 The FUTREX-5000/XL has been carefully calibrated to provide body fat estimations. The calibration is traceable to the generally accepted hyd

Seite 8

15 9) To exit this mode: Press CLEAR. In addition to estimating percent body fat, a relative body fat estimation on other sites of the body (

Seite 9

16 ! Press ENTER. The display will then show a decimal point following the number "1". The number "2" will then be di

Seite 10

17 To Estimate Another Site or Repeat an Estimation - Place the Light Wand firmly on the particular body site and follow steps outlined in 6 an

Seite 11

18 1) Purpose of the Arm Band: ! Locates the measurement site on the biceps. ! Blocks out all external light that might interfere with the

Seite 12

FUTREX-5000/XL USER'S MANUAL This manual provides you with all the information needed to operate the FUTREX-5000/XL. Table of Contents App

Seite 13

19 4) Make a ring out of the Arm Band and place your dominant arm through the center of the ring. 5) Tighten the Arm Band. 6) To locate

Seite 14

20 The FUTREX-5000/XL requires that the date be manually changed each day. Use the following procedure to change the date: 1) Press SELECT PROG

Seite 15

21 The FUTREX-5000/XL provides two analysis programs for Adult User's only: ! Fitness Analysis ! Update Analysis The Fitness Analysi

Seite 16

22 4) Enter Sex by pressing the MALE or FEMALE Key. 5) Enter Height in inches or cm (whole numbers only; e.g. 68 in. is acceptable, 68.5 will

Seite 17

23 This printout (for Adult Users only) allows you to compare your previous weight and percent body fat with your current values. To Obtain

Seite 18

24 10) Enter Original Percent Body Fat obtained from the FUTREX-5000/XL prior to starting any body fat gain/loss program (be sure to press the deci

Seite 19

The FUTREX-5000/XL can directly communicate with an external printer without need for any external computer using Futrex's unique full color

Seite 20

26 The Function Mode provides the user with 3 program options: ! Selection of Metric or English units. ! Selection of a Calorie Limit Mode.

Seite 21

27 b) To Change Between Units Press either 0 or 1 and the display will show the change. c) Press ENTER if this is correct. d) Press ENTER a s

Seite 22

28 After entering the Function Mode: 1 Press 3. The display will show either "F3 0" or "F3 1". If "F3 0" is display

Seite 23

2 1.Main Body

Seite 24

29 PROBLEM PROBABLE CAUSE CORRECTIVE MEASURES 1) Display shows "LOBAT" Batteries are low a) Replace batteries (Refer to page 3).

Seite 25

30 PROBLEM PROBABLE CAUSE CORRECTIVE MEASURES 4) Unusually high body fat estimates (40-50%) a) Too much light present during the measurement.

Seite 26

31 PROBLEM PROBABLE CAUSE CORRECTIVE EstimateS 6) Print is too light or does not print. a) Printing on wrong side of the paper. b) Wrong type

Seite 27

32 1) MEASUREMENT TECHNIQUE ! Estimation Principle: Near Infrared Interactance Technique based on technology from the United States Departmen

Seite 28

33 Summary: Key Name ZERO ADJUST : When the Display shows "Sd", insert the probe firmly into the "Optical Standard&qu

Seite 29

Printed in U.S.A.

Seite 30

3 2. Optical Standard 3. Light Wand

Seite 31

4 1. Battery Installation Insert 6 1.5V "AA" size alkaline batteries into the battery compartment located on the rear of the Main B

Seite 32

5 Remove the clear plastic cover from the printer. Start feeding the paper into the slit inside the Paper Roll Compartment by pressing the PAPER F

Seite 33

6 There are two models available: ! FUTREX-5000/XL Estimates the percent body fat of Adults only (ages 18-80) ! FUTREX-5000A/ZL Estimates

Seite 34

7 TO ESTIMATE PERCENT BODY FAT: (Is date correct? See page 17.) 1) Turn Power Switch ON. The display will show a software version number (e

Seite 35

8 9) Enter Body Frame by pressing the SMALL, MEDIUM or LARGE Key. There are many methods for measuring Frame Size. Futrex does not recommend any

Kommentare zu diesen Handbüchern

Keine Kommentare